SERVICE BULLETIN 1001 issue 1
ApplicabilityAll GEW UV systems with e-Brick lamp controllers. Frequency of e-Brick Air Filter Inspection, Cleaning and ReplacementIt is apparent that some users are not inspecting and servicing their e-Brick air filters often enough. Some e-Bricks are also operating outside of their specified ambient temperature range of +5C to +40C. Either situation can cause a temperature trip-out and either will cause premature failure of the e Brick. Please note that such failures are not covered by the GEW warranty.
Servicing your e-Brick Lamp ControllerFor your convenience the relevant sections of the e-Brick operating manual are appended to this bulletin. Please take particular note of the UV System Maintenance Schedule and the Filter Service Record. Place these in a plastic folder and fix it in a handy place on the equipment. The operator can fill in the record at the specified intervals. Additional Tips and Advice
Spares and ServicePlease email spares@gewuv.com , service@gewuv.com or click on the Contact Us button above for full contact information.
Click here to download this document and the addendum as a pdf document. |